3 or 'BASE' - Respawn in base. 4 or 'GROUP' - Respawn in your group (if there's no AI left, you'll become a seagull). 5 or 'SIDE' - Respawn into an AI unit on your side (if there's no AI left, you'll become a seagull). With this respawn type, team switch is also available to any AI controlled playable units. For 3 or Base you have to set some markers. Dec 06, 2014 This is a fairly easy tutorial on how to spawn AI in Arma III using modules. The modules, new in Arma III, make mission making much easier and cut out a lot. 3 - is the number of times you want the AI unit to respawn; 10 - is the delay in seconds after the unit dies that you want it to respawn in 'eastspawn' - is the marker postion wher you want the AI units to respawn. Arma 3 respawn ai.
![Sp daten v49 2016 Sp daten v49 2016](https://allautoinfo.org/uploads/posts/2014-10/thumbs/1412306326_e1a3fa4796017573dca8eda8c0c9b5d9.png)
Free Download BMW Standard Tools 2.12 coding software
BMW Standard Tools is the software suite distributed by BMW Group that contains several interoperating applications and drivers, including NCS Expert, WinKFP, NFS, INPA, Tool32, and others. Here is the free download link for V2.12.
Hardware:
A PC (Operating system: Win XP 32 bit /VMware Win 7 32 or 64 bit) An INPA/EDIABAS K+DCAN USB Diagnostic cable (cheap €19 in eobd2.fr)
How to setup BMW Standard Tools 2.12?
Step 1: Download BMW Standard Tools 2.12
Download here and install follow system prompts:
http://www.mediafire.com/download/qldyddn48ffzrwn/BMW+Standard+Tools+2.12.rar
Step 2: Download and install INPA
http://www.maxdown.org/download.php?file=BMW%20Inpa/Ediabas%20v5.06&host=b
Step 3: Download and install NCS Expert ENG
Download NCS-Expert software here and install
http://www.mediafire.com/download/en2xcszq46vaipm/NCSEXPER32_ENG.zip
Step 4: Download and configure INPA K+DCAN cable
Make sure your EDIABAS should already be configured to STD:OBD for use with INPA cable.
Download EDIABAS configurator here:
http://www.mediafire.com/download/x1r66eesv14lx88/ediabas+konfigurator2.0.0.exe
This tool (in C:EDIABASEdiabas-Konfigurator folder) allows you to easily change the ediabas.ini to your desired interface. So if you are switching from INPA to E-Sys you could use this to switch from STD:OBD to ENET. Set COM port for INPA cable Connect the INPA DCAN cable with PC
Install device deriver Come to My Computer>>Device Manager>>Ports (COM&LPT) In this case it's COM5. We need to change this in the obd.ini file located in the c:ediabasbin folder. Right click on your INPA cable driver for example mine is labeled 'USB Serial Port' and click on properties. Now in the property window click on the advanced tab.
Now every driver is different but the important part is the settings such as latency timer and received and transmit bytes. See pic bellow for the ideal settings. You may also change the COM port number here as well for tutorial I left it at 5. Once your changes are done we can proceed by clicking OK to accept the changes. No close all windows to return to the desktop.
Step 5: Change the OBD Browse to C:EDIABASBIN and find file obd.ini and open it with an editor (e.g Notepad) First 3 lines will look like this.. [OBD] Port=Com1 Hardware=USB Need to change the Port to reflect our INPA cable which in our case is COM port 5. So change it to look like this.. [OBD] Port=Com5 Hardware=USB When done click File -> Save and exit
NOTE: Remember which USB port you connected your cable to as plugging it into a different USB port will allocate the INPA cable to a different COM port and neither tool will see the cable until the original USB port is used again or changed in device manager and obd.ini as mentioned above.Now to test if your cable installed correctly. Plug it into the vehicle's OBD port and open INPA.
Step 6: SPDATEN Files Download and install SPDaten files (always recommend the latest)
in this case it is 50.2 until I finish zipping and upload SPDatens 51.0 and upload it to share. (Follow the instructions provided at the end of the blog labeled 'How to start WinKFP' which will explain how to import the SPDaten files to WinKFP)
Once downloaded you can now
**EDITED 10-12-2013**
For NCSExpert to install or update the daten files, copy the files from SP-daten-E##daten to the C:NCSEXPERDATENE## (where E## is whatever chassis you're updating). You will also want to copy the files from SP-daten-E##SGDAT to C:NCSEXPERSGDAT (they're not separated into different chassis in NCS Expert, so you just want to copy and paste everything to that directory. Overwrite everything it asks about). Then copy the files from SP-daten-E##ECU to C:EDIABASECU
After copying the daten files to c:NCSEXPERDATENE## copy the following files to the following locations:
copy C:NCSEXPERDATENE##*.000 C:NCSEXPERDATEN copy C:NCSEXPERDATENE##*.DAT C:NCSEXPERDATEN copy C:NCSEXPERDATENE##*.ASC C:NCSEXPERDATEN
PS: How to start WinKFP?
1. Install WinKFP and come to direction
2. After installation the directory (Drive letter):EC-APPSNFSSGDAT contains file CABI.h only, and doesn’t contains files, required for working.
3. Mount the Progman disk in virtual drive (or insert in usual DVD-drive), extract all files SP-daten-Exx.rar from directory (Drive letter):CIP-Installerbin, each one in its own directory. (You must get directories like SP-daten-Exx)
4. Now copy all *.IPO files from every directory (Drive letter):SP-daten-Exxsgdat to directory (Drive letter):EC-APPSNFSSGDAT. For this purpose better use Total Commander, it allows to overwrite elder files with newest. This directory now looks like this:
5. In the same way refresh directory (Drive letter):EDIABASEcu with files taken from (Drive letter):SP-daten-Exxecu 6. Run WinKFP
6. Run WinKFP software
7. Choose “Import/Export – Import – Assemly line data” and import all data needed from directories (Drive letter):SD-daten-ExxDATA Details how to import assembly line data are given in official manual for WinKFP
8. After importing the data, copy all files from directory (Drive letter):SD-datenE70DATAgdaten to directory (Drive letter):EC-APPSNFSDATAGDATEN, overwriting all existing files.
Microsoft.office.interop.excel 15.0.0.0. Note: If you use Progman v.30 for updating WinKFP, it has error in file GDATENSgidc.as2. Simply open this file with Notepad and delete line 165.
WinKFP is ready for programming
Hardware:
A PC (Operating system: Win XP 32 bit /VMware Win 7 32 or 64 bit) An INPA/EDIABAS K+DCAN USB Diagnostic cable (cheap €19 in eobd2.fr)
How to setup BMW Standard Tools 2.12?
Step 1: Download BMW Standard Tools 2.12
Download here and install follow system prompts:
http://www.mediafire.com/download/qldyddn48ffzrwn/BMW+Standard+Tools+2.12.rar
Step 2: Download and install INPA
http://www.maxdown.org/download.php?file=BMW%20Inpa/Ediabas%20v5.06&host=b
Step 3: Download and install NCS Expert ENG
Download NCS-Expert software here and install
http://www.mediafire.com/download/en2xcszq46vaipm/NCSEXPER32_ENG.zip
Step 4: Download and configure INPA K+DCAN cable
Make sure your EDIABAS should already be configured to STD:OBD for use with INPA cable.
Download EDIABAS configurator here:
http://www.mediafire.com/download/x1r66eesv14lx88/ediabas+konfigurator2.0.0.exe
This tool (in C:EDIABASEdiabas-Konfigurator folder) allows you to easily change the ediabas.ini to your desired interface. So if you are switching from INPA to E-Sys you could use this to switch from STD:OBD to ENET. Set COM port for INPA cable Connect the INPA DCAN cable with PC
Install device deriver Come to My Computer>>Device Manager>>Ports (COM&LPT) In this case it's COM5. We need to change this in the obd.ini file located in the c:ediabasbin folder. Right click on your INPA cable driver for example mine is labeled 'USB Serial Port' and click on properties. Now in the property window click on the advanced tab.
Now every driver is different but the important part is the settings such as latency timer and received and transmit bytes. See pic bellow for the ideal settings. You may also change the COM port number here as well for tutorial I left it at 5. Once your changes are done we can proceed by clicking OK to accept the changes. No close all windows to return to the desktop.
Step 5: Change the OBD Browse to C:EDIABASBIN and find file obd.ini and open it with an editor (e.g Notepad) First 3 lines will look like this.. [OBD] Port=Com1 Hardware=USB Need to change the Port to reflect our INPA cable which in our case is COM port 5. So change it to look like this.. [OBD] Port=Com5 Hardware=USB When done click File -> Save and exit
NOTE: Remember which USB port you connected your cable to as plugging it into a different USB port will allocate the INPA cable to a different COM port and neither tool will see the cable until the original USB port is used again or changed in device manager and obd.ini as mentioned above.Now to test if your cable installed correctly. Plug it into the vehicle's OBD port and open INPA.
Step 6: SPDATEN Files Download and install SPDaten files (always recommend the latest)
in this case it is 50.2 until I finish zipping and upload SPDatens 51.0 and upload it to share. (Follow the instructions provided at the end of the blog labeled 'How to start WinKFP' which will explain how to import the SPDaten files to WinKFP)
Once downloaded you can now
**EDITED 10-12-2013**
For NCSExpert to install or update the daten files, copy the files from SP-daten-E##daten to the C:NCSEXPERDATENE## (where E## is whatever chassis you're updating). You will also want to copy the files from SP-daten-E##SGDAT to C:NCSEXPERSGDAT (they're not separated into different chassis in NCS Expert, so you just want to copy and paste everything to that directory. Overwrite everything it asks about). Then copy the files from SP-daten-E##ECU to C:EDIABASECU
After copying the daten files to c:NCSEXPERDATENE## copy the following files to the following locations:
copy C:NCSEXPERDATENE##*.000 C:NCSEXPERDATEN copy C:NCSEXPERDATENE##*.DAT C:NCSEXPERDATEN copy C:NCSEXPERDATENE##*.ASC C:NCSEXPERDATEN
PS: How to start WinKFP?
1. Install WinKFP and come to direction
2. After installation the directory (Drive letter):EC-APPSNFSSGDAT contains file CABI.h only, and doesn’t contains files, required for working.
3. Mount the Progman disk in virtual drive (or insert in usual DVD-drive), extract all files SP-daten-Exx.rar from directory (Drive letter):CIP-Installerbin, each one in its own directory. (You must get directories like SP-daten-Exx)
4. Now copy all *.IPO files from every directory (Drive letter):SP-daten-Exxsgdat to directory (Drive letter):EC-APPSNFSSGDAT. For this purpose better use Total Commander, it allows to overwrite elder files with newest. This directory now looks like this:
5. In the same way refresh directory (Drive letter):EDIABASEcu with files taken from (Drive letter):SP-daten-Exxecu 6. Run WinKFP
6. Run WinKFP software
7. Choose “Import/Export – Import – Assemly line data” and import all data needed from directories (Drive letter):SD-daten-ExxDATA Details how to import assembly line data are given in official manual for WinKFP
8. After importing the data, copy all files from directory (Drive letter):SD-datenE70DATAgdaten to directory (Drive letter):EC-APPSNFSDATAGDATEN, overwriting all existing files.
Microsoft.office.interop.excel 15.0.0.0. Note: If you use Progman v.30 for updating WinKFP, it has error in file GDATENSgidc.as2. Simply open this file with Notepad and delete line 165.
WinKFP is ready for programming
Sp Daten V32
Aug 02, 2018 Hi Shawn, could you please send SP Daten v49, if you have it? Zoe newest SPDaten if old data are included. My Spdaten v55 are corrupt. Quote: Originally Posted by rtwaits. Hi Looking for the latest Daten files for a 2012 X5 3.5i and 2011 328i X-Drive Touring, please. Feb 24, 2013 Standard Tools & SP-DATEN: Software Download Links. Jump to Latest Follow 1 - 20 of 14740 Posts. 1; 2; 3 Go to page. 1 of 737 Go to page. DreamCar Moderator. Joined Sep 29. SP-Daten If this is your first visit, be sure to check out the FAQ by clicking the link above. Sonny with a chance games snack cart a pult disney channel. You may have to register before you can post: click the register link above to proceed. Sp Daten V49 BMW E-series Coding Tool SP-Daten Download and Installation Posted on February 12, 2018 by sales Here’s little tutorial on BMW E-series coding programs installation. Issuu is a digital publishing platform that makes it simple to publish magazines, catalogs, newspapers, books, and more online. Oct 5, 2018 - At this FB2 format PDF Converter Convert PDF Converter PDF files click a starfighter, shed a turret, or convert other formats of our torrent.